High-end infusion pump, used for heating infusions, medicines, can be used in ICU room, private room, normal wards.
This bed is with CE approval
Descriptions
l Infusion rate range
l Adjustable drop rate range: 1 /min~400 drops/min
l (step: 1 drop /min)
l Adjustable flow rate range: 1ml/h~1200ml/h
l (step 0.1ml/h)
l Purge rate: 800ml/h
l KVO rate: 1ml/h (1~300ml/h)
l 3ml/h (greater than 300ml/h)
l Infusion volume range: 1ml~9999.9ml (step: 0.1 ml)
l Maximum accumulated volume: 9999.9ml (step: 0.1 ml)
l Infusion Time range: 1min~9999min (step: 1 min)
l Infusion accuracy: Within ±3% (using calibrated high quality IV set)
l Mechanical precision: within ±2%
l Occlusion alarm threshold:
l High: 800 mmHg ± 200 mmHg (106.7kPa±26.7kPa)
l Medium: 500 mmHg ± 100 mmHg (66.7kPa±13.3kPa)
l Low: 300 mmHg ± 100 mmHg (40.7kPa±13.3kPa)
l Alarm: Infusion Complete, Empty, Faulty Signal, Misoperation, Occlusion, Door Open, Air Bubble, Low Battery, Setting Error, AC power off, Idle.
l NIBP
l Range
l Average deviation: ≤ ±5mmHg
l Standard deviation: ≤ 8mmHg
l Adult
l SYS: 40mmHg~280mmHg
l MEAN: 20mmHg~240mmHg
l DIA: 10mmHg~220mmHg
l Pediatric
l SYS: 40mmHg~220mmHg
l MEAN: 20mmHg~170mmHg
l DIA: 10mmHg~160mmHg
l Neonate
l SYS: 40mmHg~135mmHg
l MEAN: 20mmHg~110mmHg
l DIA: 10mmHg~100mmHg
l Static pressure
l Range: 0mmHg~300mmHg
l Deviation: 3mmHg
l Resolution: 1mmHg
l NIBP measurement mode
l Manual
l Cycle (automatic):
l Optional interval: 1min, 2min, 3min,4min, 5min, 10min,
l 15min, 30min, 60min, 90min
l Fast: continuous NIBP measurement, interval is 5min
l NIBP alarm
l High pressure alarm: >90mmHg-160mmHg
l Low pressure alarm: <50mmHg-90mmHg
l Accuracy: ±5%
l Overpressure protection
l Adult: 280 mmHg ±10 mmHg
l Pediatric: 237 mmHg ±3 mmHg
l Neonate: 147 mmHg ±3 mmHg
l SpO2
l Range: 0%~100%
l Resolution: 1%
l Accuracy: 70% to 100%, precision is 2%
l 0% to 69%, undefined
l SpO2 alarm
l Upper limit: 100%
l Lower limit: 90%
l Alarm value accuracy: 3%
l Alarm time accuracy: 2s
l Pulse rate
l Range: 20bpm~300bpm
l Resolution: 1bpm
l Accuracy: 3bpm
l Pulse rate alarm
l Upper limit: 120bpm
l Lower limit: 50bpm (default)
l Alarm value accuracy: 5%
l NIBP Cuff requirement
l Human body contact materials: Waterproof cloth
l Size: 515mm(L)×145mm(W), allowed deviation: ±5%
l SpO2 sensor
l Type: Finger clip type
l Wire length: 3000mm, allowed deviation: ±5%
l Human body contact materials: Silicone
l Size: 188 mm(L)×198 mm(W)×228 mm(H)
l Net weight: 2.5kg
Standard Function
* 4.3” color TFT LCD screen (LED backlight), with resolution 272×480
* Three working modes: Rate/Time/Volume mode
* Drug library with 210 kinds of medicine
* Storage 1500 history records
* Heating function, suitable for infusing in winter or there is requirement for the fluid medication temperature
* Support multi language display
* A variety of visible and audible alarm, make infusion more safe
* Standard:Drug library, History record, Heating function, Drip detector